Skip to Main Content
ADD A NEW IDEA

Adabas for z/OS

Showing 14

LBP above the Bar

Right now we are limited in the space in memory between the "line"- 16m and the "bar" (2G) The ECSA is full and our LBP's are maxed out. We have put our LFIOP up above the bar, but that makes relatively little difference. It seems like time to be ...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability 2 Under development

Securing online Event Replicator functions

As suggested in Support Incident 5220314, we would like to use ADASAF to secure Event Replicator Subsystem functions as is currently done with AOS. Specifically, we would like to secure access to SYSRPTR, as well as Administration Functions - Data...
Guest over 2 years ago in Adabas for z/OS / Event Replicator Server (ARF) / Security 0 Under development

High Watermarks - Date and Time in Shutdown-statistic

AOS shows 'High Watermarks - Date and Time' via S(elect). We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under development

AOS834: Additional filters need for all ‘Display Queue’ menus to simply production monitoring

We had a Production Problem (Incident# 5351830) where multiple users were trying to access the same record which was on hold and all of them received Record-on-Hold (RSP 145) error. Our initial concerns related to AOS (Batch & Online) were add...
Zaffer Khan over 2 years ago in Adabas for z/OS / Adabas Online System (AOS) / Usability 0 Under development

Console Message For UTIONLY Mode

If an Adabas system is started in READONLY mode, this will be shown with a console MESSAGE (ADAN01 xxxxx R E A D O N L Y = YES). If an Adabas system is started in UTIONLY mode, an appropriate message is missing. UTIONLY should get acknowledged the...
Hermann Pfeiffer over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 1 Under development

Keep Record Count in FCB

We expend about $14,000 per year in cpu costs using Adarep or AOS to read the AC blocks to get record counts. Keeping the record count in the FCB (tracking A1's,E1's, ET's,BT's) would save us this cost. Though we are a medium shop, we have 142 dat...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under development

AOS: No refresh for UQE - Display

The AOS-screen 'Display User Queue Element' has no possibility to refresh the display. For example: On screen The 'Display User Queue' we have the function-key PF 4 for refresh. We would like to see changes of the fields 'No. of Calls' an 'No. of ...
Reiner Koester over 2 years ago in Adabas for z/OS / Adabas Online System (AOS) / Usability 0 Under development

ADARES BACKOUT Requirements for DDBACK disk datasets

Please note that our environment having a project goingto start for replacing Virtual Tape Storage medium to Hard Disk Storage medium.We know the following requirements for ADARES BACKOUT:- "The BACKOUT function requires that the read backward fea...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Under development

ADASEL BACKOUT INDICATOR BYTE36

The backout indicator is not available in DISPLAY mode of ADSELIt is only available in OUTPUT EXTENDED ( or ADAPLP)Could it be added to the DISPLAY option when byte 36 is 'B' in the same way as an ADD is shown as NEWREC (also delete and update) - ...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under development

In AOS Show Target ID of Replication Instead Of Only ON

On the 'Modify File Parameters' screen in AOS the replication status of a file is shown and can get changed. The values of the field 'Replication' are ON, OFF and INACT. In case of a switched on replication showing the target ID would be more info...
Hermann Pfeiffer over 2 years ago in Adabas for z/OS / Adabas Online System (AOS) 1 Under development