Skip to Main Content
ADD A NEW IDEA

All ideas

Showing 402 of 402

Call REVUXDET when Report is stopped or Review Hub is shut down

Report Exit for Detailed Reports REVUXDET currently does not get called when the report is stopped or Review Hub is shut down. When the exit is used to write SMF records for ADABAS statistics it is necessary to get control on the 'last call' in or...
Guest almost 3 years ago in Adabas for z/OS / Adabas Review (REV) 0 Under Review

Nukleus-Shutdown-Statistic: Show Average Duration of Commands

AOS shows 'Average Duration' on the 'Command Usage'-Screen. We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

avoid "ADARSP074 - LWKP2 too small" for 24*7 databases

After Adasav restore of a very large file, and running an application to this file, the application received ADARSP074. This happened because LWKP2 was not set and Adabas calculates this part at startup(using the TOPISN of the largest file). The n...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Planned

adasel: getting actual lob field reference

//DDSIIN DD DISP=SHR,DSN=QSYSCM.DB004.PLOG.D220411 //DDCARD DD * ADARUN PROG=ADASEL,DB=004,SVC=235,DE=8393,DSF=YES /* //DDKARTE DD * SELECT ALL RECORDS FROM FILE 2811 WITH ISN = 11119 DISPLAY ALL END // instead of just giving the text 'lob field...
Ernst Chvatal almost 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 3 New

NOP - end date of a network schedule definition

Add an "end date" for a network schedule, until a network/job will be execued, see attached screen shot. Currently there is ""effective from" only. An additional field "effectitve to" is requested. This means, a job (like build NATMF 9.2.1) will b...
Georg Schmitt 4 months ago in Entire System Management and Cronus / Entire Operation (NOP) / Entire Operations GUI client (OGC) 0 Under development

Allow for I8 datatype

OpenSystems hardware has it for a long time, z/Series has it for quite a while now, so by now there is no platform NOT natively supporting 64-bit arithmetic. So please introduce an I8 datatype into Natural - on all supported platforms (and NOC as ...
Wolfgang Winter almost 3 years ago in Natural for z/OS / Natural (NAT) / Programing Syntax (Cross platforms) 1 Future consideration

High Watermarks - Date and Time in Shutdown-statistic

AOS shows 'High Watermarks - Date and Time' via S(elect). We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under development

Dynamic load of STPNAT module.

Would it be possible in z/OS to enable Natural to dynamically load STPNAT module (for example, via RCA= ). If this can be done we can decouple the Natural Nucleus from a dependency of STPNAT, and be less concerned when an STPNAT zap needs to be ap...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

EP#5820 modification of files

modification of files Requestor: D'ARVA SOCIETE Platform: MF SR-Number: 707497 Product Code: ADA Initial Importance: medium Proposal: To access (and update/store) ADABAS data on the mainframe from our Web server, we use EntireX servers (as STCs) w...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 1 Planned

ADABAS-Utilities: LPB-Limit 32 k too small

The Prefetch Buffer Size (LPB) for utilities is too small (max. 32K). We start a NATURAL-Batch-program with a multi-fetch-buffer (ADARUN PREFSBL = Single-Buffer-Length) of 4.600.000. In this Case we need about 5000 Calls to read a file with 2,3 ...
Reiner Koester over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability / Usability / Utilities 3 Planned