Environment: REV482, NAT826, ADA834, COM681
Problem: REV482 HUB Gives message REV20186: Message has no detail.
We have rev running on two DBID 50 and 53. We built a REV HUB and started it.
We then logged on to SYSREVDB on DBID 53 and set it to point at the HUBID (35).
We issued a modify command to DBID 50 f/ AD05001,review=035.
Both DBIDs then were pointed at the HUB DBID 35.
I then started a commands by hour and buffer pool report on DBID 53.
The messages below started and continued until I shut down the hub.
Unfortuneatly I purged the output because the 12M lines of output (in 4 hours) were filling spool.
I searched on empower and found several reasons for the
00000090 REV20186 - ADAIOR PUT request failed.
My problem is the message REV20186 does not have enough detail to point
me at what could be wrong.
This request is to enhance messge REV20186 to let the user know
what information is being written and where.
(I will open another problem to deal with the error causing the message).
Surly ADAIOR returns some information to the caller (REV)
that can be passed on to the user in the message. (DD name etc.)
From empower search REV20186.
REV20186 ADAIOR function request failed
Explanation
Internal error occurred.
Action
Contact your Software AG technical support representative.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
00000090 REV20186 - ADAIOR PUT request failed.
Adabas Review - REV20186 - ADAIOR PUT REQUEST FAILED
KB #:1770261Operating System Family:MF
Product:Adabas Review (REV)Operating System:z/OS
Version:4.7.3
Last Updated:29-JUN-2016
Description:
Getting REV20186 - ADAIOR PUT REQUEST FAILED intermittently and continuously on database where Review is installed.
This database was recycled to start using Review Autostarted reports instead of starting them with a batch job. The next day, it was determined that one of the wrong reports was started.
So that report was Purged and the correct one started. The error started happening after that.
Resolution:
The purge only deletes the report data, not the report definition.
Instead of the purge, refresh the report as this deletes the report data and restarts the updated report.
Adabas Review - Explanation of error REV20186
KB #:512781Operating System Family:MF
Product:Adabas Review (REV)Operating System:OS/390
Version:4.3.2
Last Updated:06-DEC-2009
Description:
Original Article Number : 512781 : Receive error message REV20186 within REVIEW hub after first call made to hub.
The manual says, "Call Software AG."
Resolution:
The Command Log offload exit code is assembled with the assembler parameter "NOALIGN", but should instead be assembled with "ALIGN". "NOALIGN" allows full words to be stored without full word boundary alignment.
Repeated REV20186 messages
Fix ID:RD472022Operating System Family:Mainframe
Product:Adabas Review (REV)Fix Type:Fix
Version:4.7.2Article ID:REV-1793
Last Updated:30. Oct 2014, 19:46Fix Release Date:30. Oct 2014
Quick Access URL:https://empower.softwareag.com/sl24sec/SecuredServices/KCFullTextASP/viewing/view.asp?KEY=523004-7770856&DSN=ITRAC&DST=UPDATE
Description:
Endless REV20186 - ADAIOR PUT request failed messages,
if RVUALT data set becomes full.
All of the following Fixes (Fix) or Service Packs (SP) must be installed to apply this Fix:
TypeFix IDFix TitleAvailability
FixRD472022Repeated REV20186 messagesDownloadable below
Use Case | Review |
Created on Brainstorm | 04.06.2017 09:00 pm |
Brainstorm ID | 4685 |