Skip to Main Content
The Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX. Please refer to the IBM Ideas Portal for these products (IBMid required).
ADD A NEW IDEA

Clear

Ideas

Showing 71 of 375

Allow String-Separator for SET DEFAULTSERVER in ALTER DATABASE DDL-Statement

We work in an IBM environment loading DDL using the ACEINT Utility. The Utility request input witch LREC=80. To cover this limitation, some Statements allow a string to be separated using the '+' Char. Example: CONNECT TO 'DD=RTE_PROD_TI;GATEWAY=c...
Christian Held about 1 year ago in CONNX 0 Under Review

Show which ADABAS-fields are defined as a descriptor in query building tools

The software engineers should have an easy access get the information, which fields are indexes fields. This information could be provided in the field list of a query builder (infonaut, jdbc test application, ...) with an additional column
Martin Walzl about 1 year ago in CONNX 1 Future consideration

NOP Defaults Avoid Inconsistent time frame

Seit NOP552 CF7 zOS werden die NOP-Defaults für spätesten Start und Endezeit eines Netzes/Jobs anscheinend genauer geprüft, d.h. bisher gleichdefinierte Zeiten führen beim Aktivieren/Reaktivieren von Netzen zur Meldung: Inkonsistenter Zeitrahmen, ...
Walter Schulte over 2 years ago in Entire System Management and Cronus / Entire Operation (NOP) 0 Planned

Extension of the shutdown command for the NOM monitor to set a time value

Using the modify command „F ESYxxx,SHUTDOWN=NOM” to shutdown the NOM monitor, the NOM monitor is working until there is "nothing" left to do. So it is not possible to get the NOM monitor down in a predictable time. The only possibility is to shutd...
Christina Möllenberg over 1 year ago in Entire System Management and Cronus / Entire Output Management (NOM) 0 Not in Plan

adavfy on LUW

add Timestamp to output: %ADAVFY-I-INDSTR, Index verification %ADAVFY-I-INDCNT, NI: used: 210, free: 1773, reusage: 17, lost: 0 %ADAVFY-I-INDCNT, UI: used: 1, free: 87, reusage: 2, lost: 1 %ADAVFY-I-INDCNT, MI: used: 9, free: 87, reusage: 2, lost:...
Guest over 4 years ago in Adabas for Linux and Cloud / Adabas (ADA-Linux) / Usability / Utilities 0 Planned

Cobol Occurs depending on records are expanded out instead of using rotated arrays/child tables

When importing and populating tables that are the result of an occurs depending on instead of requiring child tables to be create, expand the ODO out to its maximum size. This will allow the record to be repatriated to its original source without ...
William Anderson about 3 years ago in CONNX 0 Under Review

Timestamp on each fnr & on each key fnr

Hi, I would like to get from an application (for now it is Natural) 2 different variables:1 . timestamp of fnr, when the last time it was modified (insert/update/delete) 2. timestamp of each key (Desc/Super & etc) for each fnr, when it was mod...
Hezi Shirazi over 1 year ago in Adabas for Linux and Cloud / Adabas (ADA-Linux) 3 Under Review

Tracing Report Processing under Linux

Despite the documentation states so, tracing of report processing seems to be not possible with NOM running under Unix. If you choose this option (command TRACE, for instance) you'll get a screen "Trace Report Processing JES" with z/OS related inp...
Hermann Pfeiffer over 3 years ago in Entire System Management and Cronus / Entire Output Management (NOM) 2 Not in Plan

SYNP details in Plog

Plog adarec regenerate tells "Re-execute" and only gives, e.g., ADAINV INVERT=145,FIELD=XX without any details of parts this field XX should be built. This may make Plog useless unless some trail of invert job is kept. It would be nice to have ful...
Arnis Avots over 1 year ago in Adabas for Linux and Cloud / Adabas (ADA-Linux) 0 Under Review

NOP-Monitor-Status Kommandos (Anhalten, Freigeben) gegen die Tasks 51 und 91 ermöglichen

In NOP 5.5.2 (CF 3) ist es nicht möglich, beim NOP-Monitor-Status Kommandos (Anhalten, Freigeben) gegen die Tasks 51 und 91 abzusetzen. Aufgefallen ist das beim Versuch, eine Loop-Situation in der Task 51 aufzulösen. In NOP 5.4.3 ist die Eingabe d...
Walter Schulte over 3 years ago in Entire System Management and Cronus / Entire Operation (NOP) 0 Planned