Showing 43 of 377

Provide "wrap-around" Tracefiles / currently there ist only one file possible

We faced an "unexpected" behaviour of the JDBC-Server during the execution of massive parallel SQL-SELECT Statements. No idea why this happend, because we run ACE for years without any problems. The support gave the advice to enable minimum trace ...
Christian Held over 2 years ago in CONNX 0 Planned

Enable creation of SQL indexes based on ADABAS descriptors

An enhancement suggestion is to have a configuration switch for CONNX to ‘recognize’ ADABAS descriptors and tag those as SQL indexes -- so when we deploy into SQL Server .. descriptors will have indexes in SQL. Provides greater flexibility, better...
Luis Diaz over 2 years ago in CONNX 0 Planned

Printer status in NOM

Printer Control Functions : Start a printer Stop a printer - Stops immediately all the printer activities. Halt a printer - Stops the printer after it will finish the report currently printing. Move a report to another printer/user. Copy a report ...
Brouria Carni Hadass over 3 years ago in Entire System Management and Cronus / Entire Output Management (NOM) 0 Not in Plan

Authentication to a Unix/Linux user with key pairs

Customer RZF Düsseldorf uses SuSE Linux sles 15. This environment does not allow to login with userid password, the only way to authenticate is to use certification (key pairs). Please consider to implement this into NPR.
Frank Hildebrandt over 3 years ago in Entire System Management and Cronus / Entire System Server (NPR) 0 Not in Plan

Restoring Symboltables with the catching-mechanism

Deutsch: Beim „Fangen“ des Arbeitsplatzes sollen auch geöffnete Master-Symboltabellen gefangen und beim Neustart der GUI angezeigt werden. Die ist bisher nicht der Fall, denn das „Fangen“ bezieht sich nur auf folgende Punkte: • Dialoge und Ansicht...
Sven Schneider over 3 years ago in Entire System Management and Cronus / Entire Operations GUI client (OGC) 1 Not in Plan

Avoid data corruption - make ENTIRENETWORK setting the default.

See incident SI #5353554. If there is a mismatch between field lengths in the DDM used to define the table in the CDD and the FDT in Adabas - data corruption may occur. While setting the configuration parameter ENTIRENETWORK avoids this - ENTIRENE...
Bjarne Sørensen almost 4 years ago in CONNX 0 Not in Plan

Allow complete directories in the ProtectedResources setting in the jacadasv.ini

Currently we have a client that’s trying to block access to many different files due to a pentest that was done where these files could be accessed given their name. This client is already using the AllowDirectoryBrowsing=0 feature, but they are t...
Darsh Cook almost 4 years ago in JIS & JI / JIS 0 Under Review

Adjust the autobulkdelete to use no locking at all

Adjust the autobulkdelete to use no locking at all in order to gain in performance.
Stephane Moreau about 4 years ago in CONNX 0 Not in Plan

Adabas SQL Gateway - Security group LDAP interface

In the Adabas SQL Gateway CDD there is a user repository. Here you define the users that are allowed to connect with the CDD. There is also the ability to define groups of users. You grant access to tables and views to users or groups. Suggestion ...
Bjarne Sørensen over 4 years ago in CONNX 0 Planned

To be able to create CDD under linux

The CDD file creationis only possible with"Connx Data Dictionnary" Tool. In our case wecreate a CDD filebyimportingRMS Specification files from VMS Server. It should be nice to have a CDD creationtoolfor Linux, in order to simply launch (in comman...