Skip to Main Content
ADD A NEW IDEA

All ideas

Showing 71

Avoid data corruption - make ENTIRENETWORK setting the default.

See incident SI #5353554. If there is a mismatch between field lengths in the DDM used to define the table in the CDD and the FDT in Adabas - data corruption may occur. While setting the configuration parameter ENTIRENETWORK avoids this - ENTIRENE...
Bjarne Soerensen about 2 years ago in CONNX 0 Not in Plan

Adjust the autobulkdelete to use no locking at all

Adjust the autobulkdelete to use no locking at all in order to gain in performance.
Stephane Moreau over 2 years ago in CONNX 0 Not in Plan

two-way SSL handshake between the web application and ApplinX

Communication between ApplinX Server and the ApplinX Base Object (which resides on the web server or application server) can be encrypted using SSL. This means one-way SSL connection, i.e., from the web application to ApplinX. We need two-way SSL ...
Alicia Garcia Garcia over 2 years ago in ApplinX / Security 1 Not in Plan

ADABAS SQL GATEWAY / CDD administration / a way to retrieve meta data "Last update time"

Hi we operate several system environments (production, test, development etc.). Currently there are 12 environments active. Each environment has its dedicated CDD. Each CDD holds the definition of mutliple applications. The definition for a specif...
Christian Held almost 3 years ago in CONNX 0 Not in Plan

Improvement of the Stop behavior on VMS side (statistics usages on log files)

Would it be possible to have a clean stop of Connx binaries on VMS side (+add of system usage statistics of the stopped processes into the log files) instead of having a simple “stop/id” ? For now, when stopping Connx from Linux side and when co...
Stephane Moreau almost 3 years ago in CONNX 0 Not in Plan

Connx Exception error code to catch (issue on Open VMS)

Please take into consideration the exchange here below in order to improve the error code of connx. De: McGhaw, Larry [mailto:Larry.McGhaw@softwareag.com] Envoyé: lundi 5 novembre 2018 23:16 À: Jean-Philippe Lutz; MOREAU Stéphane DTSI/DSI Objet: ...
Stephane Moreau almost 3 years ago in CONNX 0 Not in Plan

Keep leadning spaces and consective spaces in a generated PDF file

I am writing in lie of Japanese customer who is using NaturalONE 8.2.5. Current implementation does not allow to keep leading spaces or consecutive spaces in a generated PDF file.As NaturalONE uses Apache FOP, the customer wanted to have an enhanc...
Guest almost 3 years ago in NaturalONE / NaturalONE (ONE) 0 Not in Plan

ONE: NATstyle: Progress view displays only the library name

During NATstyle the Progress view only displays the name of the library being checked but not the name of the modules. The name of the modules being checked should also be displayed.E.g. in case of an exception (abort) it would be helpful to see w...
Guest almost 3 years ago in NaturalONE / NaturalONE (ONE) 0 Not in Plan

NatONE: Add new filter options for Natural server view

Hi, Some developpers in our companie have really problems to use NaturalONE because they don't like the implementation of filters for the Natural server view. For us, and I agree with them, it's more convenient, more quick, to edit a program with ...
Guest almost 3 years ago in NaturalONE / NaturalONE (ONE) 1 Not in Plan

Ruler in Map editor

It would be helpful to add an option to show a ruler in map editor (because we have a special feature in column 41, and we need to spot it easily).Thanks. Gerald
Gerald BEAU almost 3 years ago in NaturalONE / NaturalONE (ONE) 4 Not in Plan