Skip to Main Content
Due to the recent acquisition by IBM, the Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX any longer. Please refer to the IBM Ideas Portal for these products from now on (IBMid required). Existing content will be migrated during the next few weeks.
ADD A NEW IDEA

Adabas (ADA-zOS)

Showing 52

Nukleus-Shutdown-Statistic: Show Average Duration of Commands

AOS shows 'Average Duration' on the 'Command Usage'-Screen. We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

avoid "ADARSP074 - LWKP2 too small" for 24*7 databases

After Adasav restore of a very large file, and running an application to this file, the application received ADARSP074. This happened because LWKP2 was not set and Adabas calculates this part at startup(using the TOPISN of the largest file). The n...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Planned

adasel: getting actual lob field reference

//DDSIIN DD DISP=SHR,DSN=QSYSCM.DB004.PLOG.D220411 //DDCARD DD * ADARUN PROG=ADASEL,DB=004,SVC=235,DE=8393,DSF=YES /* //DDKARTE DD * SELECT ALL RECORDS FROM FILE 2811 WITH ISN = 11119 DISPLAY ALL END // instead of just giving the text 'lob field...
Ernst Chvatal over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 3 New

Dynamic load of STPNAT module.

Would it be possible in z/OS to enable Natural to dynamically load STPNAT module (for example, via RCA= ). If this can be done we can decouple the Natural Nucleus from a dependency of STPNAT, and be less concerned when an STPNAT zap needs to be ap...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

EP#5820 modification of files

modification of files Requestor: D'ARVA SOCIETE Platform: MF SR-Number: 707497 Product Code: ADA Initial Importance: medium Proposal: To access (and update/store) ADABAS data on the mainframe from our Web server, we use EntireX servers (as STCs) w...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 1 Planned

ADABAS-Utilities: LPB-Limit 32 k too small

The Prefetch Buffer Size (LPB) for utilities is too small (max. 32K). We start a NATURAL-Batch-program with a multi-fetch-buffer (ADARUN PREFSBL = Single-Buffer-Length) of 4.600.000. In this Case we need about 5000 Calls to read a file with 2,3 ...
Reiner Koester about 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability / Usability / Utilities 3 Planned

Add the Adabas Control block, including command options to DEVENTLOG info

It will help to find the root cause of RC 145 if in the information provided by DEVENTLOG would include the Adabas Control block and the command options
Enrique Sambrano 6 months ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New

Customer complaining about complexity of Licence keys on mainframe

Customer complaining about complexity of Licence keys on mainframe, we have found that our customers find it difficult to implement the licence keys on mainframe. Whenever there is changes on the hardware configuration they experience problems. AD...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Future consideration

Long-Alpha field support in Replicator

“ADABAS currently supports Long-Alpha fields. We are now using Replicator to replicate from our Adabas files into Sql Server tables. Unfortunately at this time, Replicator does not seem to support replicating the long alpha fields. We would like t...
David Wilbur over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Event Replicator Server (ARF) 0 New

return additional data in a response 9/ subcode 3 case in the first 2 bytes of the ACB Additions 2

Hello, If the user session gets, resp/sub 9/3 due to TNAE-timeout or a stop user command and the user was not in transaction status, it may be possible to retry the call. But in case of TNAE-timeout or stop user during an active transaction, this ...
Tatjana Sawtschenko almost 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New