Skip to Main Content
Due to the recent acquisition by IBM, the Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX any longer. Please refer to the IBM Ideas Portal for these products from now on (IBMid required). Existing content will be migrated during the next few weeks.
ADD A NEW IDEA

All ideas

Showing 345 of 345

INSERT NEW INFORMATION IN ADAREP UTILITY

IN ADAREP MAINFRAME THERE ARE TWO INFORMATION THAT DOES NOT EXIST IN ADADREP UNIX DATE OF LAST UPDATE TIME OF LAST UPDATE IS IT POSSIBLE TO INCLUDE THESE TWO INFORMATION?--- ReRouting to Linux. Was: AIX
Guest over 3 years ago in Adabas for Linux and Cloud / Adabas (ADA-Linux) / Re-Hosting / Utilities 0 Planned

CrossReferenz Eingabebedingungen

Es ist möglich innerhalb eines Jobnetzes mehrere Jobs über Eingabebedingungen von der Verarbeitung auszuschließen. (Beispiel, Eingabebedingung Referenz=DUM, Abhängig von Symbolwert TAG EQ "Montag"). (Beispiel, EIngabebedingung Referenz=DUM, Abhän...
Volker Kautz over 3 years ago in Entire System Management and Cronus / Entire Systems Management (ESM) 0 Planned

Mecanizing Connx management

____________________________________________ Hi, Actually, to synchronize each dictionnary from production CICS to the acceptance CICS and the development CICS, I must - change using the mouse (GUI) the production z/os machine name to the targer m...
Guest over 3 years ago in CONNX 0 Under development

ADABAS SQL GATEWAY / CDD administration / a way to retrieve meta data "Last update time"

Hi we operate several system environments (production, test, development etc.). Currently there are 12 environments active. Each environment has its dedicated CDD. Each CDD holds the definition of mutliple applications. The definition for a specif...
Christian Held over 3 years ago in CONNX 0 Not in Plan

Improvement of the Stop behavior on VMS side (statistics usages on log files)

Would it be possible to have a clean stop of Connx binaries on VMS side (+add of system usage statistics of the stopped processes into the log files) instead of having a simple “stop/id” ? For now, when stopping Connx from Linux side and when co...
Stephane Moreau over 3 years ago in CONNX 0 Not in Plan

Having type 3 to be /0 compliant with the ALLOWNULLINCHAR=1

Our needs it to be able to recover data after NULL value when using type 3 "Text Expandable" field and having ALLOWNULLINCHAR enabled. Nowthe data type we are using (Text Expandable), stops at the null terminator (even withALLOWNULLINCHAR=1) Larry...
Stephane Moreau over 3 years ago in CONNX 0 Under development

Connx Exception error code to catch (issue on Open VMS)

Please take into consideration the exchange here below in order to improve the error code of connx. De: McGhaw, Larry [mailto:Larry.McGhaw@softwareag.com] Envoyé: lundi 5 novembre 2018 23:16 À: Jean-Philippe Lutz; MOREAU Stéphane DTSI/DSI Objet: ...
Stephane Moreau over 3 years ago in CONNX 0 Not in Plan

ACE - Enhance Data Dictionary Comparison Tool

The Data Dictionary Comparison Tool is a very helpful utility for comparing one CDD to another. It would be even more helpful if a CDD could be compared against an Adabas FDT. There are times I would like to knowthat allchangesmade to Adabas files...
Guest over 3 years ago in CONNX 1 Future consideration

ADADBS with ZIIP=YES brings ADARUN Error-23

An ADADBS OPERCOM ends as follows: 'ADARUN DATABASE = 009, PROG = ADADBS, ZIIP = YES ADARUN Error-23, Invalid value for parameter ZIIP' and aborts with an 'ABEND SYSTEM = 000 USER = 0035'. As a result, subsequent steps no longer start. All non-ZI...
Reiner Koester over 3 years ago in Adabas for z/OS / Usability / Utilities / zIIP 0 Future consideration

Customer would like to have Batch access to Import/Export

The Hartford would like a quote for a customer-paid product enhancement to provide command line access support for the Import/Export actions.
Darsh Cook over 3 years ago in JIS & JI 0 Under development