Skip to Main Content
Due to the recent acquisition by IBM, the Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX any longer. Please refer to the IBM Ideas Portal for these products from now on (IBMid required). Existing content will be migrated during the next few weeks.
ADD A NEW IDEA

Usability

Showing 16 of 344

#1014072 ADASEL SELECT ALL FROM USER... sh. allow WITH FILES

With ADABAS V8.2 ADASEL is enabled to select data from PLOG via USER statement, which includes all files found on PLOG. Selection via USER is a necessary and useful feature to find out for example which modifications were initiated by a certain us...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 1 Not in Plan

Auto extend of sort and temp files in utilities [--> ADAMF-122]

Auto extend sort and temp files in execution of utilities, the same as the MPM is able to auto extend ASSO and DATA when they become full.No more midnight calls because SORT SIZE TOO SMALL.
Yechiel Adar over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 1 Under Review

ADARSP 9, Sc 3 should have more differentiation

ADARSP 9, Sc 3 could have 7 different reasons: TNAE,TNAX,TNAA, STOPF, STOPI, 'security Violation' and'OP cmd with the same user ID'. This makes the analyse of RSP9,SC 3 very difficult. We need new subcodes for the different reasons, for example 4 ...
Reiner Koester over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

Nukleus-Shutdown-Statistic: Show Average Duration of Commands

AOS shows 'Average Duration' on the 'Command Usage'-Screen. We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

adasel: getting actual lob field reference

//DDSIIN DD DISP=SHR,DSN=QSYSCM.DB004.PLOG.D220411 //DDCARD DD * ADARUN PROG=ADASEL,DB=004,SVC=235,DE=8393,DSF=YES /* //DDKARTE DD * SELECT ALL RECORDS FROM FILE 2811 WITH ISN = 11119 DISPLAY ALL END // instead of just giving the text 'lob field...
Ernst Chvatal over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 3 New

ADABAS-Utilities: LPB-Limit 32 k too small

The Prefetch Buffer Size (LPB) for utilities is too small (max. 32K). We start a NATURAL-Batch-program with a multi-fetch-buffer (ADARUN PREFSBL = Single-Buffer-Length) of 4.600.000. In this Case we need about 5000 Calls to read a file with 2,3 ...
Reiner Koester about 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability / Usability / Utilities 3 Planned

ADASEL: Increase DDEXPA DD cards to maximum of 99, similar to ASSO & DATA DD Cards

We are managing VLDB ADABAS database serving the population of the country. Our national Database contains more than 150 ADABAS Files. Many a times, we are tasked with producing transactional investigations using multiple large Protection Logs ag...
Zaffer Khan 8 months ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 2 New

Printing DRIVES & DATASET info., when ADAREP is run against a SAVETAPE

We have very old backups on VTS tape system with multipledatasets (DRIVES ranging from 3-8). To know the state of the backup we ran ADAREP SAVETAPEagainst a 2007 Backup dataset, which was taken with DRIVES=3. And followinginformation is listed at ...
Zaffer Khan over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 1 Planned

Adadbs Deallocate by cylinders

The DEALLOCATE function of the ADADBS utility is accepting values for the size parameters (ACSIZE | AC2SIZE | DSSIZE | NISIZE | UISIZE) only in units of RABN blocks.Most other utilities and functions allow the provision of size values in blocks or...
Guest over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 0 Planned

Decorators to show if 'source' is running or stopped

The Event Replicator Target Adapter Administration Tool shows a navigation tree comprising all the 'engines', 'sources' and 'targets' defined under the Status branch. To figure out, if those components a re running or stopped, one has to double-cl...
Hermann Pfeiffer over 3 years ago in Adabas for z/OS / Event Replicator Target Adapter (ART) / Usability 0 Future consideration