Skip to Main Content
The Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX. Please refer to the IBM Ideas Portal for these products (IBMid required).
ADD A NEW IDEA

Clear

Ideas

Showing 116 of 382

When AFP optimization is stopped due to an internal error make it known to the user

When AFP optimization is stopped due to an internal error make it known to the user via WTO in the COR Daemon joblog or some other visible means.
Guest over 4 years ago in Adabas for z/OS / Adabas Fastpath (AFP) 0 Planned

Fastpath: new File Parameter for full exclusions statistics recorded for a file

Please refer to Support Incident5224186:It is for performance reasons that Adabas Fastpath does notattribute every command of no interest to a file-level exclusion Count.The COP1=H on an S1 command requests an action from Adabas (retain the ISN li...
Guest over 4 years ago in Adabas for z/OS / Adabas Fastpath (AFP) 0 Planned

opercom LICREFRESH for the hub

SI-576597 refresh licensekeys w/o restart
Ernst Chvatal 10 months ago in Adabas for z/OS / Adabas Review (REV) 0 Under Review

Response Code 22 Subcode 14

ADARES PLCOPY, READONLY=YES and ADASAV SAVE create a deadlock on the database, it is solved only by timeout , ADASAV gets user abend U34
Tatjana Sawtschenko 10 months ago in Adabas for z/OS / Adabas (ADA-zOS) / Utilities 6 Under Review

Replicate Empty Adabas File To An Empty Table in SQL Database

Activating replication for an empty Adabas file will not lead to the creation of an empty SQL Server table. Only when the first record is put into the Adabas file, the SQL table will be created (and a row inserted). This doesn't sound right, don't...
Hermann Pfeiffer over 4 years ago in Adabas for z/OS / Event Replicator Target Adapter (ART) 0 Under Review

Long-Alpha field support in Replicator

“ADABAS currently supports Long-Alpha fields. We are now using Replicator to replicate from our Adabas files into Sql Server tables. Unfortunately at this time, Replicator does not seem to support replicating the long alpha fields. We would like t...
David Wilbur over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Event Replicator Server (ARF) 0 New

Option to specify more than 3 parameters in DELTA SAVE Facility

We would like to request an enhancement for ADABAS DELTA SAVE Facility so as to cater to 3 or parameter options during restore. Following was an incident raised earlier on the same subject. ADASAV RESTORE DELTA (Delta/Drives/Fmove): "Quiet often...
Zaffer Khan over 4 years ago in Adabas for z/OS / Adabas Delta Save Facility (ADE) 1 Planned

return additional data in a response 9/ subcode 3 case in the first 2 bytes of the ACB Additions 2

Hello, If the user session gets, resp/sub 9/3 due to TNAE-timeout or a stop user command and the user was not in transaction status, it may be possible to retry the call. But in case of TNAE-timeout or stop user during an active transaction, this ...
Tatjana Sawtschenko almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New

Allow REV521 REVIEWB input continuation (SI-484892)

Pls allow REV521 REVIEWB input continuation (per SI-484892). In Batch Natural using REVIEWB to run Review reports in batch, the combination of report name and date/time range criteria (i.e. From & To dates, with Times) can easily exceed 71 cha...
Daniel Geary about 3 years ago in Adabas for z/OS / Adabas Review (REV) 0 New

Allow Adabas Cluster Services maintenance without downtime.

z/OS can upgrade one LPAR at a time in the cluster - but Adabas needs all cluster nuclei to be down to upgrade between releases or to apply particular zaps. Make Adabas Cluster Services able to be upgraded without downtime. From duplicate ADAMF-I-...
Bjarne Sørensen over 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Adabas Cluster Services (ALS) / HA 0 New