avoid "ADARSP074 - LWKP2 too small" for 24*7 databases

After Adasav restore of a very large file, and running an application to this file, the application received ADARSP074. This happened because LWKP2 was not set and Adabas calculates this part at startup(using the TOPISN of the largest file). The n...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Planned

ADADABS ALLOCATE/DEALLOCATE to be allowed even if file currently used

Currently, it is not possible to proceed with an ALLOCATE/DEALLOCATE of space on a file with ADADBS if a file is used ( even if is it only being read).We have got very big files (high number of records and high number of cylinders in allocation) i...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Under Review

Dynamic load of STPNAT module.

Would it be possible in z/OS to enable Natural to dynamically load STPNAT module (for example, via RCA= ). If this can be done we can decouple the Natural Nucleus from a dependency of STPNAT, and be less concerned when an STPNAT zap needs to be ap...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

LBP above the Bar

Right now we are limited in the space in memory between the "line"- 16m and the "bar" (2G) The ECSA is full and our LBP's are maxed out. We have put our LFIOP up above the bar, but that makes relatively little difference. It seems like time to be ...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability 2 Under development

ADASEL BACKOUT INDICATOR BYTE36

The backout indicator is not available in DISPLAY mode of ADSELIt is only available in OUTPUT EXTENDED ( or ADAPLP)Could it be added to the DISPLAY option when byte 36 is 'B' in the same way as an ADD is shown as NEWREC (also delete and update) - ...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under development

SPATs messages - MVS console log

Currently we receive errors of Natural programs on SPATs (triggers) in SYSOUT TSPRTnn but what we want is to receive also as these error messages on the MVS SYSLOG. It is impossible to ascend alerts automatically in real time by an alert tool (suc...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

Online reorder of data should not write gigabytes on p-log

Stop or make optional the writing of records moved by online reorder to the protection log. do this to reduce the critical recovery time (restore and regenerate). When you do an online reorder of an Adabas file in a given descriptor sequence the r...
Bjarne Soerensen over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Future consideration

Refresh buffer INFOBUFFERSIZE in Adabas

We use Adabas 826 and parameter INFOBUFFERSIZE to retrieve RSP-145 with ADADBS DEVENTLOG every 2 hours.After job, we want to refresh this buffer for not retrieve same informations.Actually, it is not possible .This function could be use in example...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Planned

REDEFINEs on SYSSPT pda STPAPARM

Any stored procedures and trigger subprograms need to use the following PDA: -------------Parameter STPAPARM ----Lib SYSSPT -----------------Env NDEV 0010 1 REQ-AREA (A200) /* Request Area 0020 1 REDEFINE REQ-AREA /* Redef. begin : REQ-AREA 0030 2...
Guest over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

EP#5820 modification of files

modification of files Requestor: D'ARVA SOCIETE Platform: MF SR-Number: 707497 Product Code: ADA Initial Importance: medium Proposal: To access (and update/store) ADABAS data on the mainframe from our Web server, we use EntireX servers (as STCs) w...