Skip to Main Content
The Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX. Please refer to the IBM Ideas Portal for these products (IBMid required).
ADD A NEW IDEA

Clear

Ideas

Showing 107 of 374

Introduce a grace period for the DCOMMITTHRESHOLD.

Introduce a new feature and parameter DCOMMITWAIT which will have the REPTOR not commit messages with less than DCOMMITTHRESHOLD transactions until DCOMMITWAIT milliseconds have passed. While it will introduce a small delay - it will allow greater...
Bjarne Sørensen over 3 years ago in Adabas for z/OS / Event Replicator Server (ARF) 0 New

ADAORD reorder with FILE= and no other parms should be an error

ADAORD REORASSO FILE=123 is a valid request that will simply reorder the entire associator - the "FILE=" parameter, while appearing to apply only to one file, actually does nothing, unlike the similar ADAORD REORFASSO FILE=123 which reorganizes ju...
Douglas Kelly over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 3 Not in Plan

TRANSACTIONS SUSPEND to show related P-log block number.

When making use of TRANSACTIONS SUSPEND and RESUME for taking a snapshot copy of the database container datasets - it would be useful if the ADADBS would write the related protection log block number of the SYNC. This block number will be needed a...
Bjarne Sørensen over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New

NOP Defaults Avoid Inconsistent time frame

Seit NOP552 CF7 zOS werden die NOP-Defaults für spätesten Start und Endezeit eines Netzes/Jobs anscheinend genauer geprüft, d.h. bisher gleichdefinierte Zeiten führen beim Aktivieren/Reaktivieren von Netzen zur Meldung: Inkonsistenter Zeitrahmen, ...
Walter Schulte over 2 years ago in Entire System Management and Cronus / Entire Operation (NOP) 0 Planned

Extension of the shutdown command for the NOM monitor to set a time value

Using the modify command „F ESYxxx,SHUTDOWN=NOM” to shutdown the NOM monitor, the NOM monitor is working until there is "nothing" left to do. So it is not possible to get the NOM monitor down in a predictable time. The only possibility is to shutd...
Christina Möllenberg over 1 year ago in Entire System Management and Cronus / Entire Output Management (NOM) 0 Not in Plan

Add the Adabas Control block, including command options to DEVENTLOG info

It will help to find the root cause of RC 145 if in the information provided by DEVENTLOG would include the Adabas Control block and the command options
Enrique Sambrano over 1 year ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Under Review

IP-Address in ADABAS REVIEW

For any 24/7 service-oriented organization that relies heavily on REVIEW Logs for monitoring/statistical purposes, a search is made to identify transactions generating errors/loops. But we are unable to find the IP-address of the source. Although,...
Arun Thomas Abraham over 4 years ago in Adabas for z/OS / Adabas Review (REV) 0 Future consideration

Make calculation of expanded file chain while nucleus is active

KB article 1765090 is related to this feature request.Sequence of events: ADASAV back up database; ADADBS delete all application files; ADAORD REORDB; ADASAV restore FMOVE all application files (expanded files in the database) back into database. ...
Guest over 4 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Under Review

Adadbs Deallocate by cylinders

The DEALLOCATE function of the ADADBS utility is accepting values for the size parameters (ACSIZE | AC2SIZE | DSSIZE | NISIZE | UISIZE) only in units of RABN blocks.Most other utilities and functions allow the provision of size values in blocks or...
Guest over 4 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 0 Planned

ADADABS ALLOCATE/DEALLOCATE to be allowed even if file currently used

Currently, it is not possible to proceed with an ALLOCATE/DEALLOCATE of space on a file with ADADBS if a file is used ( even if is it only being read).We have got very big files (high number of records and high number of cylinders in allocation) i...
Guest over 4 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Under Review