Skip to Main Content
ADD A NEW IDEA

Adabas (ADA-zOS)

Showing 18

UQ-Option setzen für bereits existierende Deskriptoren ohne ADAINV

Möchte man für bereits bestehende Deskriptoren die UQ-Option setzen, so erfordert dies dzt. einen RELEASE und anschließender Neuinvertierung des Deskriptors via ADAINV. Bei sehr großen Files mit mehreren hundert Mio Records ist ein ONLINE-Invert n...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Planned

ADARSP 9, Sc 3 should have more differentiation

ADARSP 9, Sc 3 could have 7 different reasons: TNAE,TNAX,TNAA, STOPF, STOPI, 'security Violation' and'OP cmd with the same user ID'. This makes the analyse of RSP9,SC 3 very difficult. We need new subcodes for the different reasons, for example 4 ...
Reiner Koester almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

Add back ECBS count to CLOGLAYOUT=8

This field has been available on all prior CLOGLAYOUT. It is extremely useful in determing bottleneck situations on the command queue that delay users (for example, update users during a SYN2 situation, users during other ET sync, slowdown from CI...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) 0 Planned

Nukleus-Shutdown-Statistic: Show Average Duration of Commands

AOS shows 'Average Duration' on the 'Command Usage'-Screen. We would like to see the same Information in the nucleus-shutdown-statistic.
Reiner Koester almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability 0 Planned

avoid "ADARSP074 - LWKP2 too small" for 24*7 databases

After Adasav restore of a very large file, and running an application to this file, the application received ADARSP074. This happened because LWKP2 was not set and Adabas calculates this part at startup(using the TOPISN of the largest file). The n...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 0 Planned

EP#5820 modification of files

modification of files Requestor: D'ARVA SOCIETE Platform: MF SR-Number: 707497 Product Code: ADA Initial Importance: medium Proposal: To access (and update/store) ADABAS data on the mainframe from our Web server, we use EntireX servers (as STCs) w...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / HA 1 Planned

ADABAS-Utilities: LPB-Limit 32 k too small

The Prefetch Buffer Size (LPB) for utilities is too small (max. 32K). We start a NATURAL-Batch-program with a multi-fetch-buffer (ADARUN PREFSBL = Single-Buffer-Length) of 4.600.000. In this Case we need about 5000 Calls to read a file with 2,3 ...
Reiner Koester over 2 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability / Usability / Utilities 3 Planned

Printing DRIVES & DATASET info., when ADAREP is run against a SAVETAPE

We have very old backups on VTS tape system with multipledatasets (DRIVES ranging from 3-8). To know the state of the backup we ran ADAREP SAVETAPEagainst a 2007 Backup dataset, which was taken with DRIVES=3. And followinginformation is listed at ...
Zaffer Khan almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 0 Planned

Enlarge maximum secondary allocation size for files

The maximum secondary allocation size for data storage, normal index and upper index for an Adabas file are file attributes. Their values are kept in the FCB.Unfortunately, there's only a halfword (2 bytes) provided for those values and the values...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability 0 Planned

Adadbs Deallocate by cylinders

The DEALLOCATE function of the ADADBS utility is accepting values for the size parameters (ACSIZE | AC2SIZE | DSSIZE | NISIZE | UISIZE) only in units of RABN blocks.Most other utilities and functions allow the provision of size values in blocks or...
Guest almost 3 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Usability / Utilities 0 Planned