Skip to Main Content
The Adabas & Natural Ideas Portal does not contain ideas from products ApplinX and EntireX. Please refer to the IBM Ideas Portal for these products (IBMid required).
ADD A NEW IDEA

All ideas

Showing 374 of 374

Automated Initialization of Global/Independent Variables per Session (NDV)

In our development environment, the correct i nitialization of Global and Independent variables is a mandatory prerequisite for both execution and cataloging (STOW) of Natural objects. We manage hundreds of libraries and systems , each with its ow...
Luciano Pinheiro Pimenta 5 months ago in NaturalONE / NaturalONE (ONE) / Usability 0 Under Review

Generate NATdoc valid HTML code when using XML Toolkit

Generate NATdoc comment lines instead of plain comment text in generated Natural code. I would appreciate it if the version of the XML Toolkit/NatOne is included in this comments.
Edith Schmidt about 2 months ago in NaturalONE / NaturalONE (ONE) 0 Future consideration

Seperate passphrase checks from settings for password

Passphrase checks only works if "User password history" is set to Y or *As there is no reason to combinate passphrase with password settings, it would be better to seperate this.
Christina Möllenberg about 2 months ago in Natural for z/OS / Natural Security (NSC) 0 Under Review

Cross Reference Generation Without Blocking SYSMAIN Copy

Using new SYSSEC Cross-reference option "B" would Always Generate XREF data during Catalog or Stow to be certain we will create it if we can. It would not prevent Copying or Moving Objects into the Library which are simply missing XREF. The SYSMA...
Rick Poirier 5 months ago in Natural for z/OS / Natural Security (NSC) 0 Under Review

Allow for switching transactions through WEB I/O CICS Adapater

Currently through the Web IO adapter to CICS we cannot switch to different CICS transactions once the session is started. We are forced to start a new session to access a different CICS transaction. We would like the ability to change CICS transac...
Raul Chiriboga about 2 months ago in Natural for Ajax / Natural for Ajax (NJX) 0 New

A missing CORCFG module should prevent job execution in a VISTA environment

A missing CORCFG in a VISTA environment should not be tolerated. Currently when CORCFG is missing the job produces "+COR005E Runtime configuration module CORCFG not located" message but it continues processing which could result in huge logical co...
Sias Kotze about 2 months ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New

Add info of DDSIAUS2 of ADARES PLCOPY to Checkpoint file

We do ADARES PLCOPY TWOCOPIES - DDSIAUS1 to GDG and DDSIAUS2 to a dataset with date/time in the name. DDSIAUS1 rolls over after the GDG limit is reached and DDSIAUS2 is retained for 12 or 24 months. However only the info of DDSIAUS1 is reported in...
Sias Kotze about 2 months ago in Adabas for z/OS / Adabas (ADA-zOS) 0 New

LBP above the Bar

Right now we are limited in the space in memory between the "line"- 16m and the "bar" (2G) The ECSA is full and our LBP's are maxed out. We have put our LFIOP up above the bar, but that makes relatively little difference. It seems like time to be ...
Guest over 4 years ago in Adabas for z/OS / Adabas (ADA-zOS) / Scalability 3 Under development

Correct display of "Unused Blocks" in Display File Layout with SYSAOS or ADAREP

The information on UNUSED BLOCKS of Adabas file components like AC, UI, NI or DS displayed in SYSAOS as well as with ADAREP does not reflect the real situation regarding free blocks. What is shown instead is the number of blocks never used since...
Tatjana Sawtschenko over 1 year ago in Adabas for z/OS / Adabas (ADA-zOS) / Adabas Online System (AOS) / Utilities 0 Under Review

Erweiterung des ESA Sysout Protokolls mit einem Datum

Bei einem langlaufendem ESA-Knoten ist es schwer, Meldungen, die im Sysout dokumentiert werden, einem Datum zu zuordnen. Es wird nur eine Uhrzeit dokumentiert. Beispiel: 120542 (OUT) (MSG) % ESA0309I 00261 Dynamische SERVER-Verwaltung aktiviert. (...
Volker Kautz 2 months ago in Entire System Management and Cronus / Entire Systems Management Adapter (ESA) 0 Under Review